ISO13485 M Spo2 Finger Sensor Probes Stable Soft Compatible

Med Accessories Technology Dongguan Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap ISO13485 M Spo2 Finger Sensor Probes Stable Soft Compatible from wholesalers
     
    Buy cheap ISO13485 M Spo2 Finger Sensor Probes Stable Soft Compatible from wholesalers
    • Buy cheap ISO13485 M Spo2 Finger Sensor Probes Stable Soft Compatible from wholesalers
    • Buy cheap ISO13485 M Spo2 Finger Sensor Probes Stable Soft Compatible from wholesalers

    ISO13485 M Spo2 Finger Sensor Probes Stable Soft Compatible

    Ask Lasest Price
    Brand Name : Med Accessories
    Model Number : M69A10S Soft clip
    Price :
    Certification : CE,ISO,SFDA
    Delivery Time : About one week
    Payment Terms : T/T
    • Product Details
    • Company Profile

    ISO13485 M Spo2 Finger Sensor Probes Stable Soft Compatible

    Medical consumables Compatible reusable M-o adult soft spo2 sensor

    Compatibility:

    Manufacturer

    Model

    Bitmos

    sat 800, sat 801, sat 805, sat 816, satPuls

    CAS Med

    511

    Cardio Aid

    200

    Covidien > Nellcor

    N-3000, N-390, N-395, N-550, N-560, N-595, N-600, N-6000, N-600x, NPB-290, NPB-295, Symphony N-3000

    Criticare

    506DNV3, 506DNVP3, 506LNV3, 506LNVP3, 506NV3, 506NVP3

    DRE

    Waveline

    Datex Ohmeda

    AS/3, CS/3, Cardiocap/5, S/5, enGuard CM5

    Digicare

    LW600

    Fukuda Denshi

    Dynascope DS-7100

    GE Healthcare > Critikon > Dinamap

    Carescape B650, Carescape V100, Dinamap ProCare with M Pro 1000, E-NSAT, M-NSAT Modules, Pro 1000, Pro 1000 V3, Pro 200, Pro 300, Pro 300V2, Pro 400, Pro Series, Pro Series V2, ProCare, ProCare 200, ProCare 300, ProCare 400, ProCare Ausculatory 400, ProSeries V2, V300

    Huntleigh

    All

    Invivo

    Escort II OPT30 Prism, MDE Escort Prism, T8

    M

    All

    Mediana

    YM6000

    Midmark > Cardell

    9403, 9500HD

    Mindray > Datascope

    Accutor V, Accutorr Plus, Accutorr Plus (Nellcor), Accutorr V, Duo, EPM4, Passport 2, Passport 2LT, Passport V, Passport XG, Spectrum, Spectrum OR, Trio, V12, V21

    Nihon Kohden

    BSM-2300, BSM-2304A, BSM-4100, BSM-4104A, BSM-4114A, BSM-5100

    Omron > Colin

    BP-306, BP-508, BP-808, BP-88, BP-88S, BP-S510, Press-Mate, T105NXM

    Oridion

    Capnostream 20

    Respironics

    Alice 5

    Stryker > Medtronic > Physio Control

    Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E

    Welch Allyn

    42NT0-E1 LXi, 45NE0-E1 LX, 53STP, Propaq CS, Spot Vital Signs 42MTB-E1, Spot Vital Signs 42NTB-E1, Spot Vital Signs lXi

    Zoll

    E Series, M Series, R Series

    Cleaning the equipment:

    To clean the sensor and its connecting cable, follow these steps:

    Use warm soapy water: Clean the sensor and cable by gently washing them with warm, soapy water. Ensure that the water is not too hot, and use a mild soap or detergent.

    Use a soft cloth with soapy water or 70% isopropyl alcohol: Moisten a soft cloth with either soapy water or 70% isopropyl alcohol. Gently wipe the probe and cable with the cloth, taking care not to damage the surface of the visual indicator and the detector.

    Avoid abrasive agents or chemical products: Do not use any abrasive agents or chemical products except for 70% isopropyl alcohol. These can potentially damage the sensor and its components.

    Dry the probe and cable thoroughly: After cleaning, allow the probe and cable to dry completely before using them again. Ensure that there is no moisture remaining, as this can affect the proper functioning of the equipment.

    Avoid irradiation, autoclaving, soaking, or immersing the probe: Do not subject the probe to irradiation, autoclaving, soaking, or immersion in any type of solution. These actions can damage the probe and compromise its performance.

    Keep the probe clean and dry: It is important to maintain the cleanliness and dryness of the probe during use. Regularly check for any signs of contamination or damage and clean as necessary.

    Average life expectancy: The average life expectancy of a SpO2 sensor is typically more than a year when used under the conditions recommended in the operating instructions. Following the proper cleaning and maintenance guidelines can help prolong the lifespan of the sensor.

    By following these cleaning instructions and guidelines, you can ensure the cleanliness, functionality, and longevity of the SpO2 sensor and its connecting cable.